V1-R

5/8-4"

~3100#


V1-R valve has a 4-piece assembly that allows for removal of the valve body and end cap, while the end connections remain in-line. Maintenance can now be made without the need for cutting or welding. V1-R valve experience enhanced performance, reduced downtime, and seamless service.

Ball valve

Eraway

  • Detailed Specifications
  • Feature
  • Advantage
  • Application
    • Commodity name: V1-R
    • 尺寸范围: 5/8-4"
    • 压力范围: ~3100#

    V1-R valve has a 4-piece assembly that allows for removal of the valve body and end cap, while the end connections remain in-line. Maintenance can now be made without the need for cutting or welding. V1-R valve experience enhanced performance, reduced downtime, and seamless service.

    Size 5/8” – 4”
    Pressure Classes ASME / ANSI Class 3100
    Materials of Construction Carbon steel (A105) – Standard, 
    Alloy steel (F22, F91) – Standard 
    In Compliance ASME B16.34, 
    PED ,
    Nuclear ASME III Class 1, 2 and 3,
    Nuclear Safety Related – 10CFR50 Appendix B,
    SIL
    End Connections Socketweld, Buttweld – Standard
    Shutoff Absolute Zero-Leakage Shutoff
    • Simplicity of design: 4-piece valve assembly designed for ease of removal while connections remain inline. Field testable after repair, prior to insertion
    • Through conduit design: No tortuous flow path. When open it has the highest possible Cv’s
    • Fixed position: Quarter turn: no seating torques required.
    • Hardened blowout proof stem: One piece, inserted through the body & shouldered
    • Metallic body seal ring: Increases body integrity by eliminating external leakage.
    • Live load packing gland: Minimum four bolt configuration with shallow stuffing box. Ensures consistent torque at variable pressures & temperatures
    • Hard coated & mate lapped ball and seat:  High Velocity Oxygen Fuel (HVOF) chromium carbide hard coating with a minimum hardness of 850 HV (65 HRC). Mate-lapped seats
    • Seat designs: Hard coated, both ball and integral downstream seat to the end-cap to eliminate a potential leak path
    • Stringent testing: Every valve is tested, documented, and serialized
    • Four-year warranty: The very best in the industry. Covers internal seat leakage as well as external through the packing and/or body seal.
    • 4-piece assembly that allows for removal, while end connections remain in-line. Maintenance can now be made without the need for cutting or welding. Benefit: Increased efficiencies, ease of use, reduced maintenance costs
    • Through conduit design: No tortuous flow path. When open it has the highest possible Cv’s. Minimized wear & tear. Benefit: Minimized wear & tear, reduced vibration, reduced maintenance
    • Fixed position – quarter turn: No seating torques required. Benefit: Improved safety
    • Hardened blowout proof stem: One piece, inserted through the body & shouldered. Eliminates the weak link of collared & pinned designs. Benefit: Improved safety
    • Metallic body seal ring: Increases body integrity by eliminating external leakage. Benefit: Improved reliability, zero-leakage shutoff
    • Live-loaded packing gland: Minimum four bolt configuration with shallow stuffing box. Ensures consistent torque at variable pressures & temperatures. Benefit: Increased reliability
    • Hard coated & mate lapped ball and seat: High Velocity Oxygen Fuel (HVOF) chromium carbide hard coating with a minimum hardness of 850 HV (65 HRC)
    • Seat designs: Hardcoated, both ball & integral downstream seat to the end-cap to eliminate a potential leak path. Benefit: Increased reliability
    • Stringent testing: Every valve is tested, documented & serialized. Benefit: Increased reliability, increased safety, total traceability
  • Fossil Power Applications

    • Above and below seat drains
    • Ash handling
    • Attemporator spray control
    • Boiler drains
    • Boiler feed pump isolation
    • Continuous boiler blowdown
    • Electronic relief
    • Feedwater heater drains
    • Feedwater isolation
    • Instrument isolation
    • Main steam stop
    • Recirculation
    • Seal steam regulators
    • Sight/gauge glass drains
    • Soot blower regulators
    • Startup vents
    • Steam dump
    • Turbine bypass systems
    • Turbine drain

    Nuclear Generation Applications

    • Boiler feedwater
    • Circulating water system
    • Component cooling
    • Condensate extraction
    • Condensate cooling water
    • Emergency feedwater
    • Fire protection system
    • HP safety injection
    • HP & LP heater drains
    • Heat exchanger vent & drains
    • Main steam system isolation, drain & vent
    • Power operated relief valve (PORV)
    • Pressurizer drain & vent
    • Rad waste system
    • Reactor coolant pump drain & vent
    • Reactor head vents
    • Reactor water cooling vents & drains
    • Safety injection system
    • Secondary system isolation, drain & vent
    • Service water system isolation
    • Steam generator system
    • Turbine by-pass
    • Turbine drain & vent
    • Fukushima tie ins
    • Reliable hardened vents

Previous page

Next page

Previous page

Next page

Product Inquiry